Product specs
Weight | 32.3 g |
---|---|
Dimensions | 50.8 × 25.4 × 11.8 mm |
Output | 3.3V, 5V, 12V, 15V, 24V, 48V |
Current | 833mA, 1.67A, 2.66A, 3.333A, 8A, 10A |
Input Range | 40-160Vdc |
Min-Max Tamb (°C) | -40°C, +85°C |
Weight | 32.3 g |
---|---|
Dimensions | 50.8 × 25.4 × 11.8 mm |
Output | 3.3V, 5V, 12V, 15V, 24V, 48V |
Current | 833mA, 1.67A, 2.66A, 3.333A, 8A, 10A |
Input Range | 40-160Vdc |
Min-Max Tamb (°C) | -40°C, +85°C |
URF1D_LD-40WR3 series of isolated 40W DC-DC converter products have an ultra-wide input voltage of 40-160Vdc and feature efficiency of up to 91%. Meeting reinforced isolation, input to output isolation is tested with 3000Vdc/1500Vac and the converters safely operate in an ambient temperature of -40℃ to +85℃ . Input under-voltage protection, output short circuit, over-current, over-voltage, over-temperature protection. It is ideally suiting electronic equipment and railway vehicle applications using 72V, 96V and 110V battery voltages.
Note: ①Use “H” suffix for heat sink mounting, “A2S” suffix for chassis mounting and “A4S” suffix for Din-Rail mounting. We recommend to choose modules with a heat sink for enhanced heat dissipation and applications with extreme temperature requirements.
②Minimum input voltage and start-up voltage are increased by 1V for all models with A2S (wiring) and A4S (rail) suffixes because of the input reverse polarity function.
③Exceeding the maximum input voltage may cause permanent damage.
④Efficiency is measured at nominal input voltage and rated output load; efficiencies for A2S and A4S Model’s is decreased by 2% due to the input reverse polarity protection.